VOILÀ
- 24 V DC
- Protection rating IP44
- Encoder controlled movement
- Adjusting speed
Connection |
Specifications |
Ideal for |
---|---|---|
Radio-based |
Movement control and speed regulation |
Shutters and swing shutters |
Our range
Main characteristics
- Plain-view operator for blinds and swing-shutters.
- Programmable options: maintained action, adjustable maneuvering and slow-down speed; sensitivity adjusting, slowed down start and closing and immediate closing in case of power outages, plus inverted direction of travel in case of obstruction detection.
- Works during blackouts thanks to the emergency batteries.
- Irreversible motor prevents forced entry from outside.
- Voilà is safe and runs on low-voltage (24 V) and, during power outages, the shutters can be manually controlled, by releasing and re-blocking them in any position.
- Emergency release system.
- Reinforced booms.
Technical data
Models | Power supply (V) | Power supply to motor (V) | Power (W) | Current draw (A) | Max. current draw (A) | Max. power supply (V) | Current draw at 24 V (mA) | Crown turns (rpm) | Duty/cycle (%) | Force (N) | Max. maneuvering speed (m/min) | Maneuvering time at 90° (s) | Cycles/hour | Manouvering speed (m/min) | Pinion module | Reduction ratio (i) | IP Protection rating | Operating temperature (°C) | Storage temperature (°C) | Motor’s heat protection (°C) | Length (mm) | Package dimensions (mm) | Weight (kg) | Torque (Nm) | Rpm speed (turns/min) | Weight lifted (kg)* | Duration of operation (min) | Combinations | Radio signal frequency (Mhz) | Batteries | Material | Bluetooth Radio Frequency (GHz) | Maximum speed measured at the end of the leaf (m/min) | Product standards | Compliance with directives | Max. current draw (mA) | Wireless Standard | Casing material | Operating relative humidity (%) | Temperature reading precision (°C) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
001UV01 | ÷ | ÷ | x | |||||||||||||||||||||||||||||||||||||
001VLR01DX | 230 AC | 24 DC | 75 | 3 max | HEAVY-DUTY SERVICE | 44 | -20 ÷ +55 ÷ | ÷ | 33 | x | ||||||||||||||||||||||||||||||
001VLR01SX | 230 AC | 24 DC | 75 | 3 max | HEAVY-DUTY SERVICE | 44 | -20 ÷ +55 ÷ | ÷ | 33 | x | ||||||||||||||||||||||||||||||
001UV02 | ÷ | ÷ | x | |||||||||||||||||||||||||||||||||||||
001VLR02 | 230 AC | 24 DC | 150 | 6 max | HEAVY-DUTY SERVICE | 44 | -20 ÷ +55 x 2 ÷ | ÷ | 2 x 33 | x | ||||||||||||||||||||||||||||||
001UV03 | ÷ | ÷ | x | |||||||||||||||||||||||||||||||||||||
001UV04 | ÷ | ÷ | x | |||||||||||||||||||||||||||||||||||||
001UV05 | ÷ | ÷ | x |