Key Features

The RH3+ handset offers the following features:

  • Call tone amplifier for systems with electronic call tones or AC buzz tone.
  • Adjustable volume call tone
  • Piezo buzzer for DC or AC call voltage signal
  • Latching Privacy feature for both call tone amp and piezo buzzer
  • Piezo buzzer can be used as an independent second sounder, over-riding the call tone amplifier if both operating (Alarm mode)
  • Positive or negative going door status indicator
  • Anti-lockdown circuit with over-ride

Technical Specifications

CONNECTIONS:

  • DR Door Release. A negative going voltage level to trigger the system’s lock control circuit.
  • VT 12VDC supply to the handset for LED and call tone functions.
  • 0V 0VDC supply to the handset.
  • BZ Call tone input. Either AC or DC based tones are amplified and heard through the handset when on-hook.
  • S2 Microphone signal from handset. 2.5 volt circuit at 150 ohms.
  • S1 Signal to handset speaker. Rated at 32 Ohms at a ½ Watt.
  • DS Door status LED. Operates from a high level going low or low level going high.
  • EX Extension sounder or flashing beacon output and is relative to the call tone input i.e. negative or positive with corresponding DC or AC input.
  • CB Connection to additional switch (where fitted), pulls to 0V when activated.
  • X Alarm input (Apex system)
  • ALM Connection to piezo buzzer, apply 11-15V to activate.

JUMPER LINKS:

  • LK7&LK10 Call tone / piezo buzzer select
  • LK6 Anti-lockdown circuit (Door Release outputs a 500 ms negative going trigger) / over-ride select
  • PL5 BZ input DC blocking (reduces on-site electrical interference)
  • PL3 Positive/negative going Door Status select